Abstract


Existing buildings are designed according to the relevant codes and standards for pre-defined loads. Since the loads are not certain, building standards use statistical data to define them. Therefore, during the design some loading conditions may not be considered sufficiently.  Occurrence of some hazards such as, earthquake, extreme winds, flood, impact of vehicle, missile and explosion may be different during the lifetime of the buildings that has not been considered during the design. To withstand these extreme situations and fulfill the upgraded building codes’ requirements and reduce the construction cost, retrofitting of the existing buildings are the best solution. The present paper reviews the most recent methods and techniques applied for retrofitting of the concrete buildings.

Full Text:

PDF

References


Antonopoulos, C. P., and Triantafillou, T. C. (2002). Analysis of FRP-strengthened RC beam-column joints. J. Compos. Constr., 6(1), 41–51.

Attari, N., Amziane, S., and Chemrouk, M. (2010). Efficiency of beamcolumn joint strengthened by FRP laminates. Adv. Compos. Mater., 19(2), 171–183.

Gergely, J., Pantelides, C. P., and Reaveley, L. D. (2000). Shear strengtheningofRCT-jointsusingCFRPcomposites.J.Compos.Constr.,4(2), 56–64.

Ghobarah, A., and El-Amoury, T. (2005). Seismic rehabilitation of deficient exterior concrete frame joints. J. Compos. Constr., 9(5), 408–416.

Ghobarah, A., and Said,A.(2001).“Seismic rehabilitation of beam-column joints using FRP laminates. J. Earthquake Eng., 5(1), 113–129.

Ghobarah, A., and Said, A. (2002). Shear strengthening of beam-column joints. Eng. Struct., 24(7), 881–888.

Granata, P. J., and Parvin, A. (2001). An experimental study on Kevlar strengthening of beam-column connections. Compos. Struct., 53(2), 163–171.

Mahini, S. S., and Ronagh, H. R. (2010). Strength and ductility of FRP web-bonded RC beams for the assessment of retrofitted beam-column joints. Compos. Struct., 92(6), 1325–1332.

Mahini, S. S.,and Ronagh,H.R.(2011).“Web-bonded FRPs for relocation of plastic hinges away from the column face in exterior RC joints.” Compos. Struct., 93(10), 2460–2472.

Karayannis, C.G., and Sirkelis, G. M. (2008). Strengthening and rehabilitation of RC beam-column joints using carbon-FRP jacketing and epoxy resin injection. Earthquake Eng. Struct. Dyn., 37(5), 769–790.

Parvin, A.,and Wu,S. (2008).Ply angle effect on fiber composite wrapped reinforced concrete beam-column connections under combined axial and cyclic loads. Compos. Struct., 82(4), 532–538.

Dalalbashi, A., Eslami, A., & Ronagh, H. R. (2013). Numerical investigation on the hysteretic behavior of RC joints retrofitted with different CFRP configurations. Journal of Composites for Construction, 17(3), 371-382.

Bedirhanoglu, I., Ilki, A., & Kumbasar, N. (2013). Precast fiber reinforced cementitious composites for seismic retrofit of deficient rc joints–A pilot study. Engineering Structures, 52, 192-206.

Belleri, A., Brunesi, E., Nascimbene, R., Pagani, M., and Riva, P. (2015). Seismic performance of precast industrial facilities following major earthquakes in the Italian territory. J. Perform. Constr. Facil., 10.1061/(ASCE)CF.1943-5509.0000617, 04014135.

Liberatore, L., Sorrentino, L., Liberatore, D., and Decanini, L. D. (2013). Failure of industrial structures induced by the Emilia (Italy) 2012 earthquakes. Eng. Fail. Anal., 34, 629–647.

Magliulo, G., Ercolino, M., Petrone, C., Coppola, O., and Manfredi, G. (2014). The Emilia earthquake: Seismic performance of precast reinforced concrete buildings. Earthquake Spectra, 30(2), 891–912.

Kam, W. Y., Pampanin, S., and Elwood, K. (2011). Seismic performance of reinforced concrete buildings in the 22 February Christchurch (Lyttelton) earthquake. Bull. N.Z. Soc. Earthquake Eng., 44(4), 239–278.

Binici, H. (2007). “March 12 and June 6, 2005 Bingol-Karliova earthquakes and the damages caused by the material quality and low workmanship in the recent earthquakes. Eng. Fail. Anal., 14(1), 233–238.

Tama, Y. S. (2012). Structural damages observed in state buildings after Simav/Turkey earthquake occurred on 19 May 2011. Nat. Hazard Earth Syst., 12(8), 2709–2718.

Tama, Y. S., Solak, A., Cetinkaya, N., Sen, G., Yılmaz, S., and Kaplan, H. (2013). Damages to unreinforced masonry buildings by the Van earthquakes of 23 October and 9 November 2011. Nat. Hazard Earth Syst., 13(2), 329–337.

Cakir, F., Uckan, F., Shen, J., Seker, B. S., and Akbas, B. (2015). Seismic damage evaluation of historical structures during Van earthquake, October 23, 2011.” Eng. Fail. Anal., 58(1), 249–266.

Kilci, F., Kara, B. Y., and Bozkaya, B. (2015). Locating temporary shelter areas after an earthquake: A case for Turkey. Eur. J. Oper. Res., 243(1), 323–332.

Murat, O. (2015). Field reconnaissance of the October 23, 2011, Van, Turkey, earthquake: Lessons from structural damages. J. Perform. Constr. Facil., 10.1061/(ASCE)CF.1943-5509.0000532, 04014125.

Parisi, F., and Augenti, N. (2013). Earthquake damages to cultural heritage constructions and simplified assessment of artworks. Eng. Fail. Anal., 34, 735–760.

Altin, S., Anil, O., and Kara, M. E. (2008). Strengthening of RC nonductile frames with RC infills: An experimental study. Cem. Concr. Compos., 30(7), 612–621.

Anil, O., and Altin, S. (2007). An experimental study on reinforced concrete partially infilled frame. Eng. Struct., 29(3), 449–460.

Arslan, M. H., and Korkmaz, H. H. (2007). What is to be learned from damage and failure of reinforced concrete structures during recent earthquakes in Turkey? Eng. Fail. Anal., 14(1), 1–22.

Kaplan, H., Yilmaz, S., Cetinkaya, N., and Atimtay, E. (2011). Seismic strengthening of RC structures with exterior shear walls. Sadhana, 36(1), 17–34.

Korkmaz, H. H. (2013a). Seismic performance improvement of reinforced concrete frames not designed according to TDY 2007 with external shear walls. Project No. 11101012, Selcuk Univ., Scientific Research Projects Office (BAP), Konya, Turkey.

Dere, Y. (2016). Assessing a Retrofitting Method for Existing RC Buildings with Low Seismic Capacity in Turkey. Journal of Performance of Constructed Facilities, 31(2), 04016098.

Guo, T., Xu, W., Song, L., & Wei, L. (2012). Seismic-isolation retrofits of school buildings: Practice in China after recent devastating earthquakes. Journal of Performance of Constructed Facilities, 28(1), 96-107.

Yildirim, S. Kalyoncuoglu, A. Erkus, B. & Tonguc, Y. (2015). Seismic Retrofit of Industrial Precast Concrete Structures Using Friction Dampers: Case Study from Turkey. Improving the Seismic Performance of Existing Buildings and Other Structures 2015, 693-705.




DOI: http://dx.doi.org/10.1000/ijses.v2i4.168

Refbacks

  • There are currently no refbacks.


Copyright (c) 2018 International Journal Series in Engineering Science (IJSES) (ISSN: 2455-3328)